The Run Data pane
|
|
Description
|
The Run Data pane displays the current
values for selected run parameters. The update interval is defined
in the system strategy.
The figure below displays an example of the Run Data pane:
|
|
|
How to change the appearance of the pane
|
The appearance
of the pane can be changed so that it includes more or fewer data displays.
The table below describes how this is done:
Step
|
Action
|
1
|
In System Control,
select View:Properties
or
right-click on the pane and select Properties on
the menu.
Result: The Properties dialog box is displayed.
|
2
|
Select the Run Data Groups tab
and, if desirable, do one or more of the following:
-
Select an available group to
be displayed in the list to the left.
-
Edit an
available group: Select the group from the list on the left, and
click the Edit Group button.
Modify the included readings in the list to the right, and click OK.
-
Create a
new group: Click the New group button
and select the readings that you want to view from the list. Enter
a name for the group, and click OK.
-
Delete a
group: Click the Delete Group button
and select a group in the Delete Layout dialog
box, click OK and confirm
the deletion.
|
3
|
Select the run data parameters that you want to display
in the list to the right.
|
4
|
Click OK to
view the selected items in the Run
Data pane. The name of the selected layout replaces the
default layout name Run Data.
|
|
|
|
How to change text color or text background
|
The
table describes how to change the text color or background in the
displayed reading boxes.
Step
|
Action
|
1
|
Right-click on the pane and select Properties.
Result: The Properties dialog box is displayed.
|
2
|
Select the Run Data Color tab.
|
3
|
Click the Text or Background buttons.
Select a new color, and click OK.
Result: The color
change is displayed in the test field.
|
4
|
Make further adjustments to the colors as appropriate.
|
5
|
Click OK to
apply the changes.
|
|
|
|
How to set the pressure units
|
If the Pressure reading box is displayed
in the Run Data pane, you
can set the displayed units. The table below describes how this
is done:
Step
|
Action
|
1
|
Right-click on the Pressure reading
box to display the menu.
|
2
|
Select Set Unit and
the appropriate unit (MPa, bar or psi).
Result: The selected
unit is displayed.
|
|
|
|
How to view and select manual instructions
|
Some
strategies directly link specific manual instructions to the reading
boxes in the Run Data pane.
This is indicated by a double arrow (>>).
A particular reading box can have one or more instructions attached
to it. In cases where there is more than one instruction, one of
the instructions is the main instruction.
There are two ways to view the manual instructions:
Option 1:
-
Double-click the
reading box.
Result: The dialog
box for manual instructions is displayed, showing the instruction,
or main instruction if there is more than one.
Option 2:
Result: The dialog
box for manual instructions is displayed in which you can execute
the appropriate command.
For more details on how to use manual instructions, please
see Manual
instructions.
|
|
|
2005-06-15
|
|
|